EC 160 CO2 Incubator, Nuve - Turkey, www.linhnam.com.vn
EC 160 CO2 Incubator
• Chamber volume: 160 liters
• Temperature range: Ambient temperature +7 ºC to 50 ºC
• Temperature variation / fluctuation: ±0.3 ºC at 37 ºC / ±0.1 ºC
• Programmable temperature alarm range:±0.5 ºC to 5 ºC
• Air jacketed heating system
• RaPIDcell™ fast temperature recovery without overshoot
• CO2 Range: 0 to 20 % CO2
• CO2 Variation / Fluctuation: ±0.3 % / ±0.1%
• Programmable CO2 alarm range: ±0.5 % to 5.0%
• Infra-Red CO2 level control permitting frequent access
• LifeCell™ control software to optimize parameters
• Large, bright LCD display with text messages and help
• Simultaneous display of set and actual values
• Seamless stainless steel chamber with rounded corners
• Clean chamber without any sensor inside
• NüveDis™ 90 ºC wet disinfection system
• NüveTrack™ monitoring and recall of last 72 h parameter values and alarms
• Auto Zero every 12 minutes for permanent accurate control
• 0.22µm sterile filtration of CO2, sampled gases and Auto-Zero reference air
• Typical 95% RH to protect cultures against dehydration
• Audible and visual alarms, remote alarm relay
• Remote alarm outlet
• Built-in 2nd stage gas regulator
• Three shelves
• Humidity tray
• Temperature range: Ambient temperature +7 ºC to 50 ºC
• Temperature variation / fluctuation: ±0.3 ºC at 37 ºC / ±0.1 ºC
• Programmable temperature alarm range:±0.5 ºC to 5 ºC
• Air jacketed heating system
• RaPIDcell™ fast temperature recovery without overshoot
• CO2 Range: 0 to 20 % CO2
• CO2 Variation / Fluctuation: ±0.3 % / ±0.1%
• Programmable CO2 alarm range: ±0.5 % to 5.0%
• Infra-Red CO2 level control permitting frequent access
• LifeCell™ control software to optimize parameters
• Large, bright LCD display with text messages and help
• Simultaneous display of set and actual values
• Seamless stainless steel chamber with rounded corners
• Clean chamber without any sensor inside
• NüveDis™ 90 ºC wet disinfection system
• NüveTrack™ monitoring and recall of last 72 h parameter values and alarms
• Auto Zero every 12 minutes for permanent accurate control
• 0.22µm sterile filtration of CO2, sampled gases and Auto-Zero reference air
• Typical 95% RH to protect cultures against dehydration
• Audible and visual alarms, remote alarm relay
• Remote alarm outlet
• Built-in 2nd stage gas regulator
• Three shelves
• Humidity tray